Name: Reclosing Devices
Display Field: NUMBER_29
Type: Feature Layer
Geometry Type: esriGeometryPoint
Description:
Service Item Id: 259deff919c44b5e915c574cc13cf403
Copyright Text:
Default Visibility: false
MaxRecordCount: 1000
Supported Query Formats: JSON, geoJSON
Min Scale: 0
Max Scale: 0
Supports Advanced Queries: true
Supports Statistics: true
Has Labels: false
Can Modify Layer: false
Can Scale Symbols: true
Supports Datum Transformation: true
Extent:
XMin: -9707269.140708938
YMin: 4235876.897976823
XMax: -9523753.369106166
YMax: 4347012.470440757
Spatial Reference: 102100
(3857)
Drawing Info:
Renderer:
Unique Value Renderer:
Field 1: SUBTYPECD
Field 2: NORMALSTATUS_A
Field 3: PHASEDESIGNATION
Field Delimiter: ,
Default Symbol:
Default Label:
UniqueValueInfos:
-
Value: 2,1,4
Label: Recloser, Closed, A
Description:
Symbol:
-
Value: 2,1,2
Label: Recloser, Closed, B
Description:
Symbol:
-
Value: 2,1,1
Label: Recloser, Closed, C
Description:
Symbol:
-
Value: 2,1,6
Label: Recloser, Closed, AB,AC,BC
Description:
Symbol:
-
Value: 2,1,5
Label: Recloser, Closed, AB,AC,BC
Description:
Symbol:
-
Value: 2,1,3
Label: Recloser, Closed, AB,AC,BC
Description:
Symbol:
-
Value: 2,1,7
Label: Recloser, Closed, ABC
Description:
Symbol:
-
Value: 2,0,4
Label: Recloser, Open, A
Description:
Symbol:
-
Value: 2,0,2
Label: Recloser, Open, B
Description:
Symbol:
-
Value: 2,0,1
Label: Recloser, Open, C
Description:
Symbol:
-
Value: 2,0,6
Label: Recloser, Open, AB,AC,BC
Description:
Symbol:
-
Value: 2,0,5
Label: Recloser, Open, AB,AC,BC
Description:
Symbol:
-
Value: 2,0,3
Label: Recloser, Open, AB,AC,BC
Description:
Symbol:
-
Value: 2,0,7
Label: Recloser, Open, ABC
Description:
Symbol:
-
Value: 3,1,4
Label: Sectionalizer, Closed, A
Description:
Symbol:
-
Value: 3,1,2
Label: Sectionalizer, Closed, B
Description:
Symbol:
-
Value: 3,1,1
Label: Sectionalizer, Closed, C
Description:
Symbol:
-
Value: 3,0,4
Label: Sectionalizer, Open, A
Description:
Symbol:
-
Value: 3,0,2
Label: Sectionalizer, Open, B
Description:
Symbol:
-
Value: 3,0,1
Label: Sectionalizer, Open, C
Description:
Symbol:
Transparency: 0
Labeling Info:
Advanced Query Capabilities:
Supports Statistics: true
Supports OrderBy: true
Supports Distinct: true
Supports Pagination: true
Supports TrueCurve: true
Supports Returning Query Extent: true
Supports Query With Distance: true
Supports Sql Expression: true
Supports Query With ResultType: false
Supports Returning Geometry Centroid: false
HasZ: false
HasM: false
Has Attachments: false
HTML Popup Type: esriServerHTMLPopupTypeNone
Type ID Field: SubtypeCD
Fields:
-
OBJECTID
(
type: esriFieldTypeOID, alias: OBJECTID
)
-
ANCILLARYROLE
(
type: esriFieldTypeSmallInteger, alias: ANCILLARYROLE
, Coded Values:
[0: None]
, [1: Source]
, [2: Sink]
)
-
ENABLED
(
type: esriFieldTypeSmallInteger, alias: Energized Status
, Coded Values:
[0: De-Energized]
, [1: Energized]
)
-
CREATIONUSER
(
type: esriFieldTypeString, alias: Creation User, length: 50
)
-
DATECREATED
(
type: esriFieldTypeDate, alias: Date Created, length: 8
)
-
DATEMODIFIED
(
type: esriFieldTypeDate, alias: Date Modified, length: 8
)
-
LASTUSER
(
type: esriFieldTypeString, alias: Last User, length: 50
)
-
LABELTEXT
(
type: esriFieldTypeString, alias: Label Text, length: 255
)
-
DETAIL_INFO
(
type: esriFieldTypeString, alias: Detail Information (Linked File), length: 255
)
-
SUBTYPECD
(
type: esriFieldTypeInteger, alias: Subtype
)
-
FEEDERID
(
type: esriFieldTypeString, alias: Feeder ID, length: 20
)
-
FEEDERID2
(
type: esriFieldTypeString, alias: Feeder ID 2, length: 20
)
-
OPERATINGVOLTAGE
(
type: esriFieldTypeInteger, alias: Operating Voltage
, Coded Values:
[120: 7.2 kV Grounded Wye]
, [140: 14.4 kV Grounded Wye]
)
-
CONSTRUCTIONSTATUS
(
type: esriFieldTypeInteger, alias: Construction Status
, Coded Values:
[0: Proposed]
, [5: Existing]
, [10: Waiting For Staking]
, ...5 more...
)
-
WORKORDERID
(
type: esriFieldTypeString, alias: Work Order ID, length: 20
)
-
DATE_INSTALLED
(
type: esriFieldTypeDate, alias: Date Installed, length: 8
)
-
DESCRIPTION
(
type: esriFieldTypeString, alias: Description, length: 100
)
-
ELECTRICTRACEWEIGHT
(
type: esriFieldTypeInteger, alias: Electric Trace Weight
)
-
FEEDERINFO
(
type: esriFieldTypeInteger, alias: Feeder Information
)
-
SYMBOLROTATION
(
type: esriFieldTypeDouble, alias: Symbol Rotation
)
-
MAXINTERRUPTINGCURRENT
(
type: esriFieldTypeDouble, alias: Maximum Interrupting Current
, Coded Values:
[2500: 2.5 kA]
, [4000: 4 kA]
, [6000: 6 kA]
, ...10 more...
)
-
MAXOPERATINGVOLTAGE
(
type: esriFieldTypeInteger, alias: Maximum Operating Voltage
, Coded Values:
[160: 4.16/7.2 kV]
, [210: 7.2/12.4 kV]
, [230: 7.6/13.2 kV]
, ...3 more...
)
-
NORMALSTATUS_A
(
type: esriFieldTypeInteger, alias: Normal Status - A
, Coded Values:
[1: Closed]
, [0: Open]
)
-
NORMALSTATUS_B
(
type: esriFieldTypeInteger, alias: Normal Status - B
, Coded Values:
[1: Closed]
, [0: Open]
)
-
NORMALSTATUS_C
(
type: esriFieldTypeInteger, alias: Normal Status - C
, Coded Values:
[1: Closed]
, [0: Open]
)
-
ACTUALSTATUS_A
(
type: esriFieldTypeInteger, alias: Actual Status - A
, Coded Values:
[1: Closed]
, [0: Open]
)
-
ACTUALSTATUS_B
(
type: esriFieldTypeInteger, alias: Actual Status - B
, Coded Values:
[1: Closed]
, [0: Open]
)
-
ACTUALSTATUS_C
(
type: esriFieldTypeInteger, alias: Actual Status - C
, Coded Values:
[1: Closed]
, [0: Open]
)
-
PHASEDESIGNATION
(
type: esriFieldTypeInteger, alias: Phase Designation
, Coded Values:
[4: A]
, [6: AB]
, [5: AC]
, ...4 more...
)
-
NOMINALVOLTAGE
(
type: esriFieldTypeInteger, alias: Nominal Voltage
)
-
BILRATING
(
type: esriFieldTypeInteger, alias: BIL Rating
, Coded Values:
[95: 95 BIL]
, [110: 110 BIL]
, [125: 125 BIL]
, ...5 more...
)
-
CLOSINGRESISTOR
(
type: esriFieldTypeString, alias: Closing Resistor, length: 5
)
-
GANGOPERATED
(
type: esriFieldTypeString, alias: Gang Operated Indicator, length: 5
, Coded Values:
[N: No]
, [Y: Yes]
)
-
GROUNDRESISTANCE
(
type: esriFieldTypeDouble, alias: Ground Resistance
)
-
INTERRUPTINGMECHANISM
(
type: esriFieldTypeString, alias: Interrupting Mechanism, length: 20
)
-
INTERRUPTINGMEDIUM
(
type: esriFieldTypeString, alias: Interrupting Medium, length: 5
, Coded Values:
[AIR: Air]
, [OIL: Oil]
, [PUF: Puffer]
, ...3 more...
)
-
MOUNTINGTYPE
(
type: esriFieldTypeString, alias: Mounting Type, length: 5
)
-
SCADACONTROLID
(
type: esriFieldTypeString, alias: SCADA Control ID, length: 20
)
-
SCADAMONITORID
(
type: esriFieldTypeString, alias: SCADA Monitor ID, length: 20
)
-
SHUNTMECHANISM
(
type: esriFieldTypeString, alias: Shunt Mechanism, length: 20
)
-
TIESWITCHINDICATOR
(
type: esriFieldTypeString, alias: Tie Switch Indicator, length: 5
)
-
TRIPCOUNT
(
type: esriFieldTypeInteger, alias: Trip Count
)
-
MANUFACTURER
(
type: esriFieldTypeString, alias: Manufacturer, length: 30
)
-
MODEL
(
type: esriFieldTypeString, alias: MODEL, length: 20
)
-
SERIAL_NUMBER
(
type: esriFieldTypeString, alias: Serial Number, length: 12
)
-
BREAKER_NUMBER
(
type: esriFieldTypeString, alias: Breaker Number, length: 20
)
-
NUMBER_29
(
type: esriFieldTypeString, alias: Number 29, length: 10
)
-
TYPE
(
type: esriFieldTypeString, alias: Type, length: 20
)
-
REMOTE_CONTROLLED
(
type: esriFieldTypeString, alias: Remote Controlled, length: 255
, Coded Values:
[N: No]
, [Y: Yes]
)
-
RECLOSER_SETTING
(
type: esriFieldTypeString, alias: Recloser Setting, length: 20
)
-
SECT_NUM_OPERATIONS
(
type: esriFieldTypeString, alias: Number Of Operations (Sectionalizer), length: 255
)
-
CURRENT_RATING
(
type: esriFieldTypeString, alias: Current Rating, length: 10
)
-
NEUTRAL_CURRENT_RATING
(
type: esriFieldTypeString, alias: Neutral Current Rating, length: 15
)
-
BYPASS_STATUS
(
type: esriFieldTypeInteger, alias: Bypass Status
, Coded Values:
[1: Closed]
, [0: Open]
)
-
HAS_ISOLATION_SWITCHES
(
type: esriFieldTypeString, alias: Has Isolation Switches, length: 1
, Coded Values:
[N: No]
, [Y: Yes]
)
-
WORKREQUESTID
(
type: esriFieldTypeString, alias: Work Request ID, length: 20
)
-
DESIGNID
(
type: esriFieldTypeString, alias: Design ID, length: 20
)
-
WORKLOCATIONID
(
type: esriFieldTypeString, alias: Work Location ID, length: 20
)
-
WORKFLOWSTATUS
(
type: esriFieldTypeInteger, alias: Work Flow Status
, Coded Values:
[0: None]
, [1: In Design]
, [6: Closed]
, ...15 more...
)
-
WORKFUNCTION
(
type: esriFieldTypeInteger, alias: Work Function
, Coded Values:
[0: None]
, [1: Install]
, [2: Remove]
, ...4 more...
)
-
SCADA_CONTROLLED
(
type: esriFieldTypeString, alias: Scada Controlled, length: 5
, Coded Values:
[N: No]
, [Y: Yes]
)
-
CHILD_COUNT
(
type: esriFieldTypeInteger, alias: CHILD_COUNT
)
-
DESCRIPTIVE_ADDRESS
(
type: esriFieldTypeString, alias: Descriptive Address, length: 255
)
-
OHSTRUCTUREOBJECTID
(
type: esriFieldTypeInteger, alias: OHSTRUCTUREOBJECTID
)
-
SUBSTATIONOBJECTID
(
type: esriFieldTypeInteger, alias: SUBSTATIONOBJECTID
)
-
UNIT
(
type: esriFieldTypeString, alias: UNIT, length: 20
, Coded Values:
[M3-13IR: M3-13IR]
, [VM3-10-015-EF2: VM3-10-015-EF2]
, [VM3-10-025-00E: VM3-10-025-00E]
, ...31 more...
)
-
PRI_CURRENT_SETTING
(
type: esriFieldTypeDouble, alias: PRI_CURRENT_SETTING
)
-
COMPANY_NUMBER
(
type: esriFieldTypeString, alias: COMPANY_NUMBER, length: 20
)
-
JOB_NUMBER
(
type: esriFieldTypeString, alias: JOB_NUMBER, length: 50
)
-
UNDERBUILT
(
type: esriFieldTypeString, alias: UNDERBUILT, length: 20
, Coded Values:
[T: TOP]
, [M: MIDDLE]
, [B: BOTTOM]
, ...5 more...
)
-
OWNERSHIP_CODE
(
type: esriFieldTypeString, alias: OWNERSHIP_CODE, length: 20
)
-
GlobalID
(
type: esriFieldTypeGlobalID, alias: GlobalID, length: 38
)
-
SHAPE
(
type: esriFieldTypeGeometry, alias: Shape
)
-
SubSource
(
type: esriFieldTypeSmallInteger, alias: SubSource
, Coded Values:
[0: No]
, [1: Yes]
)
-
CircuitSourceID
(
type: esriFieldTypeInteger, alias: CircuitSourceID
)
-
BI_EQUP_MAP_LOC_NBR
(
type: esriFieldTypeInteger, alias: BI Equip Map Loc Number
)
-
of_outg_cd
(
type: esriFieldTypeString, alias: of_outg_cd, length: 3
)
-
gs_outg
(
type: esriFieldTypeString, alias: gs_outg, length: 15
)
-
gs_sticky_note_sw
(
type: esriFieldTypeString, alias: gs_sticky_note_sw, length: 5
)
-
GS_ABNORMAL_STATE
(
type: esriFieldTypeString, alias: GS_ABNORMAL_STATE, length: 5
)
-
NISC_Export
(
type: esriFieldTypeString, alias: NISC_Export, length: 5
)
-
LAT
(
type: esriFieldTypeDouble, alias: LAT
)
-
LONG
(
type: esriFieldTypeDouble, alias: LONG
)
-
OHStructure_GlobalID
(
type: esriFieldTypeGUID, alias: OHStructure_GlobalID, length: 38
)
-
Substation_GlobalID
(
type: esriFieldTypeGUID, alias: Substation_GlobalID, length: 38
)
-
LEGACY_OID
(
type: esriFieldTypeInteger, alias: MED OID
)
-
LEGACY_MODELID
(
type: esriFieldTypeString, alias: MED MapWise Element, length: 255
)
-
LEGACY_PARENTID
(
type: esriFieldTypeString, alias: MED MapWise Parent, length: 255
)
-
LEGACY_FEEDER_NAME
(
type: esriFieldTypeString, alias: MED Feeder Name, length: 255
)
-
COMMENTS
(
type: esriFieldTypeString, alias: Comments, length: 255
)
-
MED_GS_GUID
(
type: esriFieldTypeString, alias: MED_gs_guid, length: 255
)
-
MED_GS_SUBSTATION
(
type: esriFieldTypeString, alias: MED_gs_substation, length: 255
)
-
MED_GS_FEEDER_NUMBER
(
type: esriFieldTypeString, alias: MED Feeder Number, length: 255
)
-
MED_GS_GUID_OHSTRUCTURE
(
type: esriFieldTypeString, alias: MED OHStructure guid, length: 255
)
-
DISTRICT
(
type: esriFieldTypeString, alias: DISTRICT, length: 10
, Coded Values:
[2: WIL]
, [4: CAN]
, [3: WMS]
, ...2 more...
)
-
SCADANetworkDevice_GlobalID
(
type: esriFieldTypeGUID, alias: SCADANetworkDevice_GlobalID, length: 38
)
-
FIBER
(
type: esriFieldTypeString, alias: FIBER, length: 50
, Coded Values:
[Yes: Yes]
, [No: No]
)
Types:
ID: 3
Name: Sectionalizer
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
OPERATINGVOLTAGE:
Inherited
-
CONSTRUCTIONSTATUS:
Inherited
-
MAXINTERRUPTINGCURRENT:
Inherited
-
MAXOPERATINGVOLTAGE:
Inherited
-
NORMALSTATUS_A:
Inherited
-
NORMALSTATUS_B:
Inherited
-
NORMALSTATUS_C:
Inherited
-
ACTUALSTATUS_A:
Inherited
-
ACTUALSTATUS_B:
Inherited
-
ACTUALSTATUS_C:
Inherited
-
PHASEDESIGNATION:
Inherited
-
NOMINALVOLTAGE:
Coded Values:
[70: 2.4 kV]
, [290: 14.4 kV]
, [330: 24.9 kV]
, ...1 more...
-
BILRATING:
Inherited
-
GANGOPERATED:
Inherited
-
INTERRUPTINGMEDIUM:
Inherited
-
TYPE:
Coded Values:
[ETS: ETS]
-
REMOTE_CONTROLLED:
Inherited
-
SECT_NUM_OPERATIONS:
Coded Values:
[1: 1]
, [2: 2]
, [3: 3]
-
CURRENT_RATING:
Coded Values:
[15: 15]
, [25: 25]
, [35: 35]
, ...2 more...
-
BYPASS_STATUS:
Inherited
-
HAS_ISOLATION_SWITCHES:
Inherited
-
WORKFLOWSTATUS:
Inherited
-
WORKFUNCTION:
Inherited
-
SCADA_CONTROLLED:
Inherited
-
UNIT:
Coded Values:
[VM3-40: VM3-40]
-
DISTRICT:
Inherited
ID: 1
Name: Circuit Breaker
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
OPERATINGVOLTAGE:
Coded Values:
[120: 7.2 kV Grounded Wye]
, [140: 14.4 kV Grounded Wye]
, [180: 161.7 kV]
, ...1 more...
-
CONSTRUCTIONSTATUS:
Inherited
-
MAXINTERRUPTINGCURRENT:
Inherited
-
MAXOPERATINGVOLTAGE:
Inherited
-
NORMALSTATUS_A:
Inherited
-
NORMALSTATUS_B:
Inherited
-
NORMALSTATUS_C:
Inherited
-
ACTUALSTATUS_A:
Inherited
-
ACTUALSTATUS_B:
Inherited
-
ACTUALSTATUS_C:
Inherited
-
PHASEDESIGNATION:
Inherited
-
NOMINALVOLTAGE:
Coded Values:
[100: 4 kV]
, [190: 8 kV]
, [300: 15 kV]
, ...3 more...
-
BILRATING:
Inherited
-
CLOSINGRESISTOR:
Coded Values:
[N: No]
, [Y: Yes]
-
GANGOPERATED:
Inherited
-
INTERRUPTINGMEDIUM:
Inherited
-
MANUFACTURER:
Coded Values:
[ABB: ABB/Westinghouse]
, [BB: Brown Boveri]
, [CPR: Cooper/McGraw Edison]
, ...4 more...
-
BREAKER_NUMBER:
Coded Values:
[134: 134]
, [144: 144]
, [154: 154]
, ...39 more...
-
TYPE:
Coded Values:
[Oil: Oil]
, [Vacuum: Vacuum]
, [SF6: SF6]
-
REMOTE_CONTROLLED:
Inherited
-
BYPASS_STATUS:
Inherited
-
HAS_ISOLATION_SWITCHES:
Inherited
-
WORKFLOWSTATUS:
Inherited
-
WORKFUNCTION:
Inherited
-
SCADA_CONTROLLED:
Inherited
-
OWNERSHIP_CODE:
Coded Values:
[MTEMC: MTEMC]
, [TVA: TVA]
, [NISSAN: NISSAN]
, ...3 more...
-
DISTRICT:
Inherited
ID: 2
Name: Recloser
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
OPERATINGVOLTAGE:
Inherited
-
CONSTRUCTIONSTATUS:
Inherited
-
MAXINTERRUPTINGCURRENT:
Inherited
-
MAXOPERATINGVOLTAGE:
Inherited
-
NORMALSTATUS_A:
Inherited
-
NORMALSTATUS_B:
Inherited
-
NORMALSTATUS_C:
Inherited
-
ACTUALSTATUS_A:
Inherited
-
ACTUALSTATUS_B:
Inherited
-
ACTUALSTATUS_C:
Inherited
-
PHASEDESIGNATION:
Inherited
-
NOMINALVOLTAGE:
Coded Values:
[100: 4.16 kV]
, [290: 14.4 kV]
, [330: 24.9 kV]
, ...1 more...
-
BILRATING:
Inherited
-
GANGOPERATED:
Inherited
-
INTERRUPTINGMEDIUM:
Inherited
-
MOUNTINGTYPE:
Coded Values:
[PAD: Pad Mounted]
, [POL: Pole Mounted]
, [SUB: Substation Frame]
-
TIESWITCHINDICATOR:
Coded Values:
[N: No]
, [Y: Yes]
-
TYPE:
Coded Values:
[4E: 4E]
, [CMR: CMR]
, [E: E]
, ...21 more...
-
REMOTE_CONTROLLED:
Inherited
-
RECLOSER_SETTING:
Coded Values:
[0A-3B: 0A-3B]
, [1A-2B: 1A-2B]
, [2A-2B: 2A-2B]
, ...2 more...
-
BYPASS_STATUS:
Inherited
-
HAS_ISOLATION_SWITCHES:
Inherited
-
WORKFLOWSTATUS:
Inherited
-
WORKFUNCTION:
Inherited
-
SCADA_CONTROLLED:
Inherited
-
UNIT:
Inherited
-
DISTRICT:
Inherited
ID: 4
Name: Circuit Switcher
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
OPERATINGVOLTAGE:
Coded Values:
[160: 46 kV]
, [170: 69 kV]
, [180: 161.7 kV]
-
CONSTRUCTIONSTATUS:
Inherited
-
MAXINTERRUPTINGCURRENT:
Inherited
-
MAXOPERATINGVOLTAGE:
Inherited
-
NORMALSTATUS_A:
Inherited
-
NORMALSTATUS_B:
Inherited
-
NORMALSTATUS_C:
Inherited
-
ACTUALSTATUS_A:
Inherited
-
ACTUALSTATUS_B:
Inherited
-
ACTUALSTATUS_C:
Inherited
-
PHASEDESIGNATION:
Inherited
-
NOMINALVOLTAGE:
Coded Values:
[100: 4.16 kV]
, [330: 24.9 kV]
, [370: 34.5 kV]
, ...3 more...
-
BILRATING:
Inherited
-
GANGOPERATED:
Inherited
-
INTERRUPTINGMEDIUM:
Inherited
-
MANUFACTURER:
Coded Values:
[SC: S&C]
, [SS: SS]
, [SM: Siemens]
-
TYPE:
Coded Values:
[HORZ: Horizontal]
, [VERT: Vertical]
-
REMOTE_CONTROLLED:
Inherited
-
CURRENT_RATING:
Coded Values:
[800: 800]
, [1200: 1200]
, [2000: 2000]
, ...1 more...
-
BYPASS_STATUS:
Inherited
-
HAS_ISOLATION_SWITCHES:
Inherited
-
WORKFLOWSTATUS:
Inherited
-
WORKFUNCTION:
Inherited
-
SCADA_CONTROLLED:
Inherited
-
UNDERBUILT:
Inherited
-
OWNERSHIP_CODE:
Coded Values:
[MTEMC: MTEMC]
, [TVA: TVA]
, [NISSAN: NISSAN]
, ...3 more...
-
DISTRICT:
Inherited
ID: 5
Name: Ground Switch
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
OPERATINGVOLTAGE:
Coded Values:
[160: 46 kV]
, [170: 69 kV]
, [180: 161.7 kV]
-
CONSTRUCTIONSTATUS:
Inherited
-
MAXINTERRUPTINGCURRENT:
Inherited
-
MAXOPERATINGVOLTAGE:
Inherited
-
NORMALSTATUS_A:
Inherited
-
NORMALSTATUS_B:
Inherited
-
NORMALSTATUS_C:
Inherited
-
ACTUALSTATUS_A:
Inherited
-
ACTUALSTATUS_B:
Inherited
-
ACTUALSTATUS_C:
Inherited
-
PHASEDESIGNATION:
Inherited
-
NOMINALVOLTAGE:
Coded Values:
[100: 4.16 kV]
, [330: 24.9 kV]
, [370: 34.5 kV]
, ...3 more...
-
BILRATING:
Inherited
-
CLOSINGRESISTOR:
Coded Values:
[N: No]
, [Y: Yes]
-
GANGOPERATED:
Inherited
-
INTERRUPTINGMEDIUM:
Inherited
-
REMOTE_CONTROLLED:
Inherited
-
BYPASS_STATUS:
Inherited
-
HAS_ISOLATION_SWITCHES:
Inherited
-
WORKFLOWSTATUS:
Inherited
-
WORKFUNCTION:
Inherited
-
SCADA_CONTROLLED:
Inherited
-
UNDERBUILT:
Inherited
-
OWNERSHIP_CODE:
Coded Values:
[MTEMC: MTEMC]
, [TVA: TVA]
, [NISSAN: NISSAN]
, ...3 more...
-
DISTRICT:
Inherited
Supported Operations:
Query
Query Attachments
Generate Renderer
Return Updates
Iteminfo
Thumbnail
Metadata